Mecca Power Generator for Telecom 25kVA 35kVA 45kVA 50kVA 55kVA 60kVA 65kVA 70kVA 75kVA Air/Water Cooled Dalian Deutz Diesel Genset

Starting from

SAR 94,875

Specifications

Listing typeProduct
Minimum order1

About this product

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators. Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled. - Brand new air cooled Beinei diesel engine generators ; -1000pcs 20-75kVA/YearWater/Air Cooled Engine -Remote Control -Continuous Running -Double Stacking -With Big Fuel Tank -Automatic Fuel Feeding - Set mounted with Deepsea DSE6020 digital controller. Breaker included. - 24V DC Electric start system with maintenance free starting batteries and battery chargers . - Low Noise -- Cylinder liner and crankcase are all made in high strength grey cast iron (German standard) with optimal design to reduce the noise and vibration - Package: Generators will be packed in poly foam. Specification Powered by BEINEI 50HZ 220-440V 17-124KVA Model LTP PRP Engine Fuel Cons. Cylinder Displacement Gov. Dimention Weight KVA / KW KVA/KW Model Origin L/H(100%) L L*W*H (MM) KGS MC17AD 17 13 15 12 F2L912 CN 3.96 2L/NA 1.880 M 1460*900*1170 588 MC28AD 28 22 25 20 F3L912 CN 6.62 3L/NA 2.828 M 1460*900*1170 680 MC33AD 33 26 30 24 F4L912 CN 8.68 4L/NA 3.770 M 1650*900*1170 764 MC39AD 39 31 35 28 F4L913 CN 9.22 4L/NA 4.086 M 1850*820*1200 890 MC44AD 44 35 40 32 F4L912T CN 11.13 4L/TC 3.770 M 1850*820*1200 970 MC55AD 55 44 50 40 F6L912 CN 13.02 4L/NA 5.655 M 2250*820*1240 1080 MC61AD 61 48 55 44 F6L913 CN 13.84 4L/NA 6.128 M 2250*820*1240 1120 MC69AD 69 55 63 50 F6L912T CN 16.55 4L/TC 5.655 M 2250*820*1240 1200 MC83AD 83 66 75 60 BF4L913 CN 15.70 4L/TC 4.086 E 2250*820*1240 1320 MC99AD 99 79 90 72 BF6L913 CN 23.88 4L/TCA 6.128 E 2250*820*1240 1320 MC124AD 124 99 113 90 BF6L913C CN 29.85 4L/TCA 6.128 E 2250*820*1240 1480 General Feature ♦ Assembled by diesel engine and Brushless alternator. Three filters as standard, fuel and water separator as optional. ♦ Radiator and fan with safety guard. ♦ Single bearing alternator IP 23, Insulation Class H. ♦ Heavy duty steel as base frame and 8hrs operation base fuel tank. ♦ Automatic control panel and 3 poles circuit breaker, internal cable. ♦ 12V or 24V battery, battery wires. ♦ Battery and float battery charger as standard supply scope. ♦ Fuel level indicator in meter and panel ♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. MORE SPEC. CONTACT US... Genset Workshop Customerized Fuel Tank 1.Volume: 500L, 1000L,1500L,2000L,3000L etc. 2.Plate steel construction 3.Fuel level meter 4.Fuel transfer systems 5.Double wall 6.Electric fuel pump 7.Fuel level sensor (indicated on control module) 8.Fuel automatic filling system 9.Tank in genset base, top, built-in, seperately stand etc Payment Terms: By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. Delivery: Approximately 2-4 weeks upon order confirmation. Service Guarantee: Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information. After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date. During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets . Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request. CKD:Complete Knock Down Generator Generator completely knocked down into parts without assembling. All items from following are seperately packed without connection. SKD:Semi Knock Down Generator Partially assembled generator. Part of the following items you choose will be assembled. Advantage: Prompt delivery Reduced tax to win more competition Lower transportation fees to save cost Localized production to win more tenders. Increased production to offer more job opportunity for the government Item Service Option Delivery Time 1 Engine Doosan, Mtu, Mitsubishi, SME, Volvo, Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect. Marine and industry use Diesel, gas 2-45days 2 Alternator Stamford, Leroysomer, Meccalte, Marathon and customer requested alternators Medium and high voltage, Marine and industry use High IP Grade CT Drop kits, PMG, AVR 2-15 days 3 Radiator Fast, Beworld brand Original Radiator come with engine Local made radiator with authorization by engine supplier 2-7days 4 Canopies Powder coated and form mounted canopy,completely break down with hings, locks, raincap,bolts,screws, etc. Exhaust pipe and flanges Standard silent type canopy package Denyo type canopy package Rental type canopy package Telecom type canopy package Super silent type canopy package Containerized type canopy package Customerized type canopy package 10days 5 Base frame Standard base or simple iron base Anti-Vibration mountings With/without tank, base tank volume no limited Fuel gauges and high pressure fuel pipes 3days 6 Control system Controller: ComAp, DeepSea, Datacom, SmartGen etc. Breaker:Delixi,ABB, Chint, etc. Battery switch, battery charger, emergency stop botton, indicator, meters, CT and all wiring and harness. Batteries and cables Speed & lub oil & water temp sensors, A package of standard parts for assembly 3days 7 Exhaust System Industrial and residential silencer Flexible connects and elbow 3days 8 Others Special demands -----------------------------------------------------------------------------------------------MAINTENANCE--------------------------------------------------------------------------------------------- General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light) Icon Indicator Light Reason Fault Analysis Low oil pressure alarm Low oil pressure alarm When oil pressure does not reduce normally, the light is on. -General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. High water temperature alarm High water temperature alarm When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. Low fuel level alarm Low fuel level alarm When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. Battery charger fault alarm Battery charger fault alarm If the charging system has fault, when engine running, the light is off. -Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. Crank failure alarm Crank failure alarm When the generator set failed three times (or six times) in a row starting, the light is on. -Oil supply system or re-start the system failure caused. Overload or breaker tripping alarm Overload or breaker tripping alarm When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. -In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance) 1. Check Daily Report of Genset . 2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage. 4. Check the Air filter. The air filter should be replaced when necessary . 5. Release fuel tank and fuel filter's water and sediment. 6. Check the water cooling filter. 7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect. 9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net. B Level Maintenance Interval (Less than 400 hours) 1. Repeatedly check A Level Daily Maintenance steps. 2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute. 4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact. 5. Replace the cooling system and add coolant concentration. 6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows: 1. Repeatedly check A and B Level Daily Maintenance steps. 2. Remove the tap of valve, clean and wash oil dirt and sludge. 3. Fasten snails from each part (including running parts and fixed parts) 4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine. 5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary. 6. Check and adjust valve clearance. 7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary. 8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat. Current Repair (D Level Maintenance)(3000-4000 hours) 1. Check valve, valve seat and other wearing, repair or change it when necessary. 2. Check P pump, quality of injection, repair and adjust it when necessary. 3. Check and adjust connecting rod and fastening twisting torque. 4. Check and adjust valve clearance. 5. Check the trip of injector. 6. Check and adjust tension of fan and generating belt. 7. Clean and wash accumulation of carbon in inlet pipes. 8. Clean and wash the core of air cooler. 9. Clean and wash the whole oil lubrication system. 10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron. Medium Repair (6000-8000 hours) 1. Including the items of minor repair. 2. Disassemble generator(except crankshaft) 3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary. 4. Check fuel supplying system, adjust oil pump and injector. 5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator. Overhaul (9000-15000hours) 1. Including the items of intermediate repair. 2. Disassemble all the parts in the generator. 3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector 5. Replace a whole set of repair tools for turbo charger and a repair set for water pump. 6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Request a quote